OMM / MI12

目前本页还没有简体中文版。您可以使用Google的翻译服务查阅 自动翻译。 我们不负责提供该项服务,而且翻译结果未经过我们的检查。
如果您需要更多帮助,请 联络我们

网页内容下载致电当地的办事处 在线联系我们

OMMThe OMM optical receiver is used in conjunction with the MI 12 interface.

The MI 12 interface processes signals between one or two optical transmitters (OMMs) and the CNC control.

OMM / MI 12 provides legacy transmission method and has now been superseded by the OMI-2 and OMI-2T.

The OMM-C / MI 120 variant allows for integration into the machine spindle nose.

About OMM

OMMThe OMM unit comprises an optical receiver that communicates with a spindle or turret mounted probe. Probe trigger and control signals are processed by the separate MI 12 interface, located in the machine tool control cabinet.

 

 

About MI 12

MI 12 interfaceThe MI 12 replaces the earlier MI4 and MI7 interface units.

 

 

 

MI 12   MI 12-B   MI12E
The standard MI 12 unit is contained within a free standing enclosure with an optional panel mounting kit also available   The MI 12-B is a board only version for mounting within the machine cabinet  

Designed for MP10E and MP700E high-power optical transmission probing systems on large machining centres and 5-axis machines.

 

About OMM-C and MI 120

OMM-C and MI 120The OMM-C / MI 120 is an alternative to the OMM / MI 12, providing the same capability in a package that can be integrated into the machine's spindle housing.

The OMM-C / MI 120 is suitable for use with Heidenhain and Siemens controllers.

 

 

Ordering information

Part number Description
A-2033-0576 OMM optical receiver
A-2075-0142 MI 12 machine interface
A-2075-0141 MI 12-B interface board only
A-2075-0323 MI12E machine interface
A-2075-0252 MI 12 interface DIN - rail mount

Useful links

OMI

OMI-2

OMI-2T