SiGNUM™ RSLM直线光栅系统

目前本页还没有简体中文版。您可以使用Google的翻译服务查阅 自动翻译。 我们不负责提供该项服务,而且翻译结果未经过我们的检查。
如果您需要更多帮助,请 联络我们

网页内容下载致电当地的办事处 在线联系我们

SiGNUM™ RELM systemThe new RSLM stainless steel spar scale offers performance to rival fine pitch glass scales yet is available in lengths up to 10 m. RSLM offers a total accuracy (including slope and linearity) better than ±4 μm over a 5 m length – an industry first! With ±30 nm cyclic error, unique filtering optics, resolution to 5 nm and simple installation, SiGNUM™ RSLM retains all of the benefits of a 20 μm encoder yet provides the performance of a fine pitch system.

RSLM 20 µm pitch stainless steel scale

SiGNUM™ RSLM stainless steel scale20 µm RSLM stainless steel scale is perfect for long travel applications where metrology can not be compromised.

  • The robust spar scale is available in defined lengths up to 10 m
  • Total accuracy better than ±4 µm over a 5 m length
  • Thermal expansion: 10.8 µm/m/°C
  • RSLM can be coiled for simple storage and handling, yet once uncoiled behaves as a spar scale
  • Mounted using specially formulated adhesive tape or mechanical clips
  • IN-TRAC™ auto-phase optical reference mark, bi-directionally repeatable even at maximum speed (12.5 m/s)
  • Multiple IN-TRAC™ reference mark positions: scale mid-point (RSLM), scale end-point (RSLE), distance coded for short travel indexing (RSLD) or regularly spaced for customer selection (RSLC)
  • Dual optical limits provide on-scale end-of-travel indication

SR readhead and Si interface features and benefits

  • SiGNUM RELM system imageCyclic error of ±30 nm, offering 'fine pitch' encoder performance
  • Capable of operation up to 12.5 m/s and 85 °C
  • Excellent signal stability in conditions unsuitable for most open optical encoders
  • Si interface offers industry standard analogue and digital outputs
  • User selectable gain control (AGC) maintains 1 Vpp analogue signal amplitude
  • Integral LEDs on readhead and interface for optimum set-up and system diagnosis
  • High flex UL approved cable – up to 10 m between readhead and interface
  • Optional IP68 in-line connector available

Compare the SR with alternative optical linear readheads.

SiGNUM™ software

Multilingual SiGNUM™ softwareSiGNUM™ software is PC based and provides comprehensive calibration, set-up optimisation and real-time diagnostics to simplify installation and system maintenance. The Si interface is connected to the PC via a mini USB connector.

  • "Real time", remote monitoring of signal level and system performance, including signal strength meter, Lissajous plot and IRED feedback meter (AGC drive), to assist with system optimisation
  • Pitch adjustment indicator enables fine adjustment of the readhead pitch
  • Quick and simple remote calibration of the reference mark and incremental signals
  • System alerts warn the user of conditions that are less than optimum (warning function) and of any errors that occur (alarm function)
  • Technical "info" guide provides contextual help and a detailed explanation of system functions and fault-finding
  • System configuration page displays Si interface configuration detailing resolution, clock frequency, etc.
  • Multilingual user interface allows the user to select from English, German, Italian and Japanese

Download SiGNUM software now.

Technical specifications

Readhead dimensions 14.8 mm x 36.0 mm x 16.5 mm (H x L x W)
Outputs (resolution)

RS422: 5 µm, 1 µm, 0.5 µm, 0.2 µm, 0.1 µm, 50 nm, 20 nm, 10 nm, 5nm.

Analogue: 1Vpp

Interpolation Si interface (x4 to x4000)
Reference mark IN-TRAC™ auto-phase optical
Limit switches Customer positioned optical dual limits
Maximum speed 12.5 m/s
Ride height tolerance

0.8 ±0.08 mm

Scale types 20 µm RSLM stainless steel scale
Vacuum compatible No 

Additional resources

Accessories and external interpolation options

For further information and product options, visit the encoder product configurator.

后续步骤